KINGTONE ELECTRONICS COMPANY
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
2 Core Silicone Fire Resistant cable , Low Smoke Fire Alarm Cable with Copper Conductor
Quick Detail:
()-FRLS cable
2 Cores Copper Conductor
Silicone Insulation
Fire Resistance Low Smoke
200m Reel, Carton, Pallet
180 minutes under fire of 750 degrees without short-circuit.
More details please contact us!
Description:
KT1400 ()-FRLS Fire Resistant cable 2 Cores Silicone
is a specific type of fire alarm cable Produced by KINGTONE. These cables are used for
installation in fire systems for connecting fire alarms etc. The cable can be installed
in dry and moist areas as well for fixed open air installation. This cable type with
electrostatic screening (St) protects the transmission circuits against extern-electrical
interferences. And all these cables comply to:
IEC60331-23-2003
IEC60332-3-22-2005
IEC61034-2-2005
EC60754-1-99
IEC60754-2-99
IEC60331-21:1999
BS EN 61034-2:2005
BS 7629-1:2008
BS EN 50267-2-1:1999
KINGTONE using best raw material and best worker to produce R ()-FRLS
Unshielded 2 Cores to meet high performance in practical application. ()-FRLS
Unshielded 2 Cores is packed in 200m Reel, 2~10 Reels /Carton, then will be layed on
pallet to protect the spool and easier carry.Because of good managing methods,
KINGTONE’S price of ()-FRLS Unshielded 2 Cores is not high although
our quality is really high.
Applications:
These cables are used for installation in fire systems for connecting fire alarms etc.
The cable can be installed in dry and moist areas as well for fixed open air installation.
This cable type with electrostatic screening (St) protects the transmission circuits
against extern-electrical interferences.
KT1400 ()-FRLS Fire resistant cable 2 Cores Copper Silicone Insulation |
|||||
APPLICATION: | |||||
These cables are used for installation in fire systems for connecting fire alarms etc. The cable can be installed in dry and moist areasas well for fixed open air installation. This cable type with electrostatic screening (St) protects the transmission circuits against externelectrical interferences. |
|||||
Standards: | |||||
All these cables comply to: | |||||
IEC60331-23-2003 IEC61034-2-2005 IEC60754-2-99 |
IEC60332-3-22-2005 IEC60754-1-99 IEC60331-21:1999 |
BS 7629-1:2008 BS EN 61034-2:2005 BS EN 50267-2-1:1999 |
|||
Fire Testing: | |||||
180 minutes under fire of 750 degrees without short-circuit. | |||||
ELECTRICAL DATA (AT20OC): | |||||
Minimum Bend Radius |
Related Search
Wireless Smoke Fire Alarm
Fire Shield Cable
Fire Rated Cable
Cable Conductor
Fire Alarm
Smoke Fire Detector
More>>
Find more related products in following catalogs on Hisupplier.com |